Free Delivery
99% Positive Feedbacks
365 days for free return
Payment Secure System
Only Best Brands
-
PROBES
HIOKI P2000 DC High Voltage Pr…
0 out of 5(0)SPECIFICATIONS
- Maximum Input Voltage : DC 2000 V
- Maximum rated line-to-ground voltage
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V - Input Resistance : 20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
- Overload Protection :
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) - Output Terminal : 4 mm banana terminal
- Operating Temperature Range : -25°C to 65°C (-13°F to 149°F)
- Operating Humidity Range : −25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing)
40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) - Storage temperature and humidity range : -30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing)
- Standards : EN 61010
- Included Accessories : Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1
FEATURES
- Enables high voltage measurement up to CAT Ⅲ 2000 V
- Safely measure solar installations like the mega-solar without interrupting the grid
- Connects to compatible Hioki clamp meters and digital multimeters (DMMs)
ACCURACY FOR COMPATIBLE INSTRUMENTS
- DT-4261 :
Range 600.0 V: Combined accuracy ±0.5% rdg ±0.2 V
Range 2000 V: Combined accuracy ±0.5% rdg ±5 V - CM4141-50 ; CM4371-50 ; CM4373-50 ; CM4375-50 :
Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V
Range 2000 V: Combined accuracy ±1.0% rdg ±3 V - DT-4282 ; DT-4281 :
Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10) - DT-4252 ; DT-4253 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10) - DT-4255 ; DT-4256 :
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10)
SKU: n/a -
POWER SUPPLY
BEETECH 3005 30V DC REGULATED …
0 out of 5(0)SPECIFICATION
TECHNICAL SPECIFICATION
- Voltage output range : 0 – 30V
- Current output range : 0 – 5A
- Current and voltage display model : A means pointer display, D means LED display
- Display precision Pointer display : ± 2.5%
- Digital display : ± 1% ± 1 word
PARAMETER SPECIFICATION
- Input voltage: AC 220V ± 10% (switch to choose) 50/60Hz
- Operating condition : -10˚C ~ 40˚C, ≤ 90%RH
- Storage condition : -10˚C ~ 40˚C, ≤ 80%RH
- Voltage stability : ≤ 0.01% + 2mV
- Load stability : ≤ 0.01% + 2mV
- Recovery time : ≤ 100µs
- Ripple and noise : ≤ 1mVrms (effective value)
- Temperature coefficient : ≤ 200PPM˚C
FEATURES
- DC Regulated Power Supply is an easy to use, low ripple high regulation precision instrument.
- It is particularly suitable for experimental development and low voltage applications.
- Its unique feature is over load protection, which makes it a safe power source for testing of electronic equipment.
- The power supply’s output is floating i.e., either the positive or negative output is connected to the chasis or ground.
- Thus the power supply may be used as a positive or negative DC source by grounding -ve or +ve terminal respectively.
SKU: n/a -
POWER GUARD
MECO PG 09 20A POWERGUARD
0 out of 5(0)SPECIFICATIONS :
- RMS VOLTAGE : 240V AC (Nominal) (195V ~ 265Vrms)
- RMS CURRENT : (0.110 ~ 20.00) Arms
- ACTIVE POWER : (0.026 ~ 4.800) KW,@240VAC (KW)
- APPARENT POWER : (0.026 ~ 4.800) KVA,@240VAC (KVA)
- REACTIVE POWER : (0.026 ~ 4.800) KVAr,@240VAC (KVAr)
- POWER FACTOR : (0.026 ~ 0.120) KW,(0.120 ~ 4.800) KW
- LINE FREQUENCY : 45.00 ~ 55.00 Hz
- ACTIVE ENERGY : 000000 ~ 999999 KWh
FEATURES :
- Three Pin Socket and Plug Suitable for Indian Socket
- Large Dual Row LCD Display with Backlight and Annunciators
- Memory Retention (KWh, EUT)
- Simple, Easy and Accurate
- Continuous Measurements
- Counts CO2 generated by Electrical Equiptment (0.555kg CO2 is generated by using 1 KWh Energy)
SKU: n/a -
PHASE SEQUENCE INDICATOR
MECO PSI 2016 PHASE SEQUENCE I…
0 out of 5(0)SPECIFICATIONS :
- AC RANGE : 60 – 600V
- RANGE : 40 – 400Hz
- DIMENSION : 100 X 60 X 24.5 mm
FEATURES :
- 3 Phase Sequence Indication via LED & Buzzer
– Reverse Phase Indication via LED & Buzzer
– Open Phase Indication via LED & Buzzer
SKU: n/a
-
DIGITAL INSULATION TESTER
Fluke 1503 Insulation Resistan…
0 out of 5(0)SPECIFICATIONS
- AC/DC Voltage Measurement
Range : 600.0 V
Resolution : 0.1V
Accuracy : 50 Hz to 400 Hz ±(% of Rdg + Digits) ±(2% + 3) - Earth Bond Resistance Measurement
Range : 20.00 Ω to 20.00 kΩ
Resolution : 0.01 Ω to 0.01 kΩ
Accuracy : ±(1.5% + 3) - Insulation Specifications
Range : 0.01 MΩ to 2000 MΩ
Test Voltage : 500 V, 1000 V
Test Voltage Accuracy : + 20%, – 0% - Storage temperature : -40°C to 60°C (-40°F to 140°F)
- Operating temperature : -20°C to 55°C (-4°F to 131°F)
- Vibration : Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
- Safety : Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
- Certifications : CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
- Size : 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
- Weight : 550g
- IP Rating : IP40
FEATURES
- A rugged, compact insulation resistance tester for residential and commercial electricians
- Performs insulation tests from 0.01 MΩ to 2000 MΩ
- Offers two insulation test voltages: 500 V and 1000 V
- Includes live circuit detection to prevent insulation test if voltage >30 V is detected
- Measures resistance from 0.01 Ω to 20.00 kΩ
SKU: n/a - AC/DC Voltage Measurement
-
DIGITAL INSULATION TESTER
HTC 6250IN Digital Insulation …
0 out of 5(0)SPECIFICATIONS
- Testing Voltage : 1000/2500/5000V
- OUT VOLTAGE : 90~110% of the test voltage
- RANGE : 0.1MΩ~200GΩ
- RESOLUTION : 0.01MΩ
- ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 5 digits ; 10~200GΩ ± 10% of rdg + 5 digits
AC VOLTAGE
-
- RANGE : 0 – 600V
- RESOLUTION : 1V
- ACCURACY : ±2.0% of rdg + 5 digits
FEATURES
- 3½ Digit Insulation Tester with Backlight
- 1,999 Count
- Data Hold
- Auto Ranging
- 3 in 1 Insulation Resistance Phase Testing / Voltage Testing & Adaptor
- POWER: AA 1.5V X 8
- Standard Accessories : Hard Carrying Case, Test Lead, Manual, Power Adaptor
- Dimension : 190(H) x 155(W) x 75(D)m
SKU: n/a -
DIGITAL INSULATION TESTER
HIOKI IR-3455 High Voltage Ins…
0 out of 5(0)SPECIFICATIONS
- Test Voltage : 250 V to 5.00 kV DC, (Possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kV)
- Measurement Range :
0.00 MΩ to 500 GΩ (250 V)
0.00 MΩ to 1.00 TΩ (500 V)
0.00 MΩ to 2.00 TΩ (1 kV)
0.00 MΩ to 5.00 TΩ (2.5 kV)
0.00 MΩ to 10.0 TΩ (5 kV) - Measurement Current : 1 mA (Test voltage 250 V to 1.00 kV), 0.5 mA (Test voltage 1.10 kV to 2.50 kV) 0.25 mA (Test voltage 2.60 kV to 5.00 kV), Short-circuit current: 2 mA or less
- Resistance Range : 10 MΩ to 10 TΩ, 7 ranges (auto range)
- Accuracy :
±5% rdg. ±5 dgt. Up to [Test voltage (setting value)/Resistance measurable at 100 nA]
±20% rdg. ±5 dgt. [Test voltage (setting value)/Resistance measurable at 100 nA] to [Test voltage (setting value)/Resistance measurable at 1 nA] or 500 GΩ
±30% rdg. ±50 dgt. [Test voltage (setting value)/Resistance measurable at 1 nA] or 501 GΩ to 9.99 TΩ - Leakage current measurement : 1.00 nA to 1.20 mA, 6 ranges (current measurement that occurs when test voltage is generated)
Accuracy ±2.5% rdg. ±5 dgt. (1 mA range); refer to complete catalog for other ranges - Voltage measurement : ±50 V to ±1.00 kV DC, 50 V to 750 V AC (50/60 Hz),
Accuracy: ±5 % rdg. ±5 dgt. , Input resistance: Approx. 10 MΩ - Temperature measurement : -10.0 ˚C to 70.0 ˚C, 3 ranges (used with optional sensor)
Accuracy ±1.0 ˚C (0.0 ˚C to 40.0 ˚C); refer to complete catalog for other ranges - Other Functions : Insulation Diagnosis (Temperature compensation, PI/DAR display, Step voltage test), Data memory, Communication (USB 2.0, PC application software), auto discharge, hot conductor warning indication, etc.
- Digital LCD, max. 999 dgt. with backlight, Bar graph display
- Dimensions and Mass : 260 mm (10.24 in)W × 250.6 mm (9.87 in)H × 119.5 mm (4.70 in)D, 2.8 kg (98.8 oz)
- Included Accessories : Test lead 9750-01 ×1, Test lead 9750-02 ×1, Test lead 9750-03 ×1, Alligator clip 9751-01 ×1, Alligator clip 9751-02 ×1, Alligator clip 9751-03 ×1, Instruction manual ×1, LR6 (AA) alkaline batteries ×6, USB cable ×1, PC application software (CD-R) ×1
FEATURES
- Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
- Wide testing voltage range, up to 5.00 kV from 250 V DC
- Wide measurement insulation range, up to 10 TΩ
- PI (Polarization Index) and DAR (Dielectric Absorption Ratio) automatically calculated / display
- Extended operating temperature range of -10°C to 50°C
- Data memory function to reduce handwritten notes
- Bright LED luminous scale
SKU: n/a -
DIGITAL INSULATION TESTER
HTC 6350 IN Insulation Resista…
0 out of 5(0)SPECIFICATIONS
- Testing Voltage : 100/250/500/1000/2500/5000 V
- OUT VOLTAGE : 90~110% of the test voltage
- RANGE : 0.1M 20G for 100/250/500 V ; 0.1M 200G for 1000/2500/5000 V
- RESOLUTION : 0.01MΩ
- ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 10 digits ; 10~200GΩ ± 10% of rdg + 5 digits
AC VOLTAGE
-
- RANGE : 0 – 600V
- RESOLUTION : 1V
- ACCURACY : ±2.0% of rdg + 5 digits
FEATURES
- 3½ Digit Insulation Tester with Backlight
- 1,999 Count
- Data Hold
- Test Range 100 V to 5000 V
- POWER: AA 1.5V X 8 (Rechargeable Battery)
- Standard Accessories : Soft Carrying Case, Test Lead, Manual, Power Adaptor,AA 1.5V X 8 (Rechargeable Battery)
- Dimension : 190(H) x 155(W) x 75(D)mm
SKU: n/a
Best Selling products
- Top 10
- PROBES
- POWER SUPPLY
- POWER GUARD
- PHASE SEQUENCE INDICATOR
- pH/EC/TDS/TEMP METER
- PH Meter
- MULTIMETER
- Multifunction Meter
- MOISTURE METER
- MILLI OHM METER
- METAL DETECTOR
- LUX METER
- LINE LASER
- LEAKAGE CLAMP TESTER
- LCR METER
- FUNCTION GENERATOR
- FORCE GAUGE
- ELECTRO MAGNETIC FIELD TESTER
- EARTH RESISTANCE TESTER
- DISTANCE METER
- DISSOLVED OXYGEN METER
- DIGITAL OSCILLOSCOPE
- DIGITAL INSULATION TESTER
- DIGITAL CALIPERS
- DIAL GUAGE
- DETECTOR
- DATA LOGGER
- COATING THICKNESS METER
- CO2 AND HUMIDITY METER
- CLAMPMETER
- CARBON MONOXIDE METER
- CAPACITANCE METER
- BREATH ALCOHOL ANALYSER
- BATTERY CAPACITY TESTER
- ANEMOMETER
- ANALOG INSULATION TESTER
- ALTIMETER
Recent products
-
FUNCTION GENERATOR
BEETECH FG-1601 FUNCTION GENER…
0 out of 5(0)- Waveform : Sine, square, triangle and TTL with symmetry
- Amplitude : 0 to 0.2V, 2V, 20V Vpp
- Sine distortion : < 1%
- Frequency range : 1Hz to 1MHz with digital frequency counter
- Frequency accuracy : ± 5% of full scale
- Output impedance : 50 Ω ± 10%
- DC offset : ± 10V
- Power : 230V ± 10%, 10VA
- Dimensions : 240 (L) x 200 (W) x 85mm (H)
- Weight : ≈ 3Kg
FEATURES
- Sine wave, triangular wave, square wave and TTL wave outputs.
- Low distortion
- Minimal sag at frequencies as low as 1Hz
- Offset control to shift baseline
SKU: n/a -
FORCE GAUGE
HTC FG-20KG Force Gauge
0 out of 5(0)SPECIFICATIONS
- Resolution : 0.01 Kg/0.01 LB/0.05 Newton
- Min. Display : 0.01 Kg/0.01 LB/0.05 Newton
- Accuracy : ± (0.5 % + 2 d), within 23 ± 5C .
- Unit select : Kg/LB/Newton
- Update time : Fast Approx. 0.2 second, Slow Approx. 0.6 second
- Measure Capacity : 20.00 Kg/44.10 LB/196.10 Newton.
- Operating Temperature : 0 to 50 ( 32 to 122 ).
- Operating Humidity : Less than 80% RH.
SKU: n/a -
ELECTRO MAGNETIC FIELD TESTER
HTC EMF-522 Electro Magnetic F…
0 out of 5(0)SPECIFICATIONS
- Range : 200/2000mG, 20/200μT
- Resolution : 0.1/1mG or 0.01/0.1μT
- Frequency Response : 30~300Hz
- Sensor : Single Axis
- Accuracy : ±(2.5%+6dgt) at 50Hz/60Hz
- Sample rate : 2.5 times per second
- Operating Temperature & Humidity : 5~40˚C, below 80% RH
- Storage Temperature & Humidity : -10~60˚C, below 70% RH
FEATURES
- 3½ Digits LCD
- 1,999 Counts
- Over Load : LCD display “OL”
- Battery Life : Approximate 100 hours
- POWER : 9V (6F22) X 1
- Standard Accessories : Soft Carrying Case, Manual
- Dimension : 130(H) x 56(W) x 38(D)mm
SKU: n/a -
EARTH RESISTANCE TESTER
HIOKI FT-6031-50 Earth Tester
0 out of 5(0)SPECIFICATIONS
- Measurement System : Two-electrode method/three-electrode method (switchable)
- Measurement range / Accuracy :
20 Ω (0 Ω〜20.00 Ω) / ±1.5% rdg ±8 dgt
200 Ω (0 Ω〜200.0 Ω) / ±1.5% rdg ±4 dgt
2000 Ω (0 Ω〜2000 Ω) / ±1.5% rdg ±4 dgt - Earth voltage : 0〜30.0 V rms
Accuracy : ±2.3% rdg ±8 dgt (50 Hz/60 Hz), ±1.3% rdg ±4 dgt (DC) - Allowable earth potential : 25.0 V rms (DC or sine wave)
- Dustproof and waterproof : IP65/IP67 (EN60529)
- Dimensions : 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D
- Mass : 570 g (20.1 oz.) (including batteries and protector, excluding terminal covers and other accessories)
FEATURES
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Excellent noise resistance
- IP67 protected – top of the industry
- Minimize cabling time with innovative earthing rods and cable winder
- Wide 0Ω to 2000Ω measurement range
- Test all ground types from Class A to Class D with a single meter
SKU: n/a -
EARTH RESISTANCE TESTER
CIE DET-2000 Digital Earth Tes…
0 out of 5(0)PECIFICATIONS
- Display : 3.5 digits,L.C.D
- Accuracy :
0% to 10% of the range…….+3%
10% to 90% of the range……+1.5%
90% to 100% of the range……+3% - H.V Test : 2KV AC For 1 min. Between electrical circuit and containing case
- Insulation Resistance Test : More than 25M Ohm at 500V dc between electrical circuit
FEATURES
- Rugged ABS Body
- 0-10 — 1000 Ohm
- Easy to use hand held meter
- Ni-cd rechargeable cells
- Facility as to make bench top type instrument
- Four terminals
- Designed to measure the resistance of earth used in power circuit
SKU: n/a -
DISTANCE METER
BOSCH GLM 30-23 Laser Measure
0 out of 5(0)- Laser Diode : 635 nm, < 1 mW
- Measurement range : 0.15 – 30.00 m
- Weight, approx. : 0.09 kg
- Measurement time, typical : 0.5 s
- Units of measurement : m/cm
- Laser class : 2
- Measurement accuracy, typical : ± 1.5 mmᵈ
- Measurement time, max. : 4.2 s
- Power supply : 2 x 1.5 V LR03 (AAA)
- Automatic deactivation : 5 min
- Laser colour : Red
- Measuring range, up to : 30m
SKU: n/a -
DISTANCE METER
BOSCH GLM 100-25C Laser Measur…
0 out of 5(0)TECHNICAL DETAILS
- Measuring range, up to : 100 m
- Dust and splash protection : IP 54
- Measurement time, typical : < 0.5 s
- Units of measurement : m/cm, ft/inch
- Laser diode : 650 nm, < 1 mW
- Measurement range : 0.08 – 100.00 m
- Laser class : 2
- Measurement accuracy, typical : ± 1.5 mmᵈ
- Measurement range of incline measurement : 0 – 360° (4 x 90°)
- Measuring accuracy (typical) : ± 0.2°* (*plus use-dependent deviation)
- Measurement time, max. : 4 s
- Power supply : 3 x 1.5 V LR6 (AA)
- Automatic deactivation : 5 min
- Weight, approx. : 0.23 kg
- Memory capacity (values) : 50
- Tripod thread : 1/4″
- Digital viewfinder : integrated
- Data transfer : Bluetooth™ 4.2 Low Energy
- Laser color : Red
SKU: n/a -
DISSOLVED OXYGEN METER
LUTRON DO-5509 DISSOLVED OXYGE…
0 out of 5(0)SPECIFICATIONS
- Display : 13 mm ( 0.5″ ) LCD, 3 1/2 digits.
- Measurement Range : Dissolved Oxygen – 0 to 20.0 mg/L.
- Resolution : 0.1 mg/L.
- Accuracy : ± 0.4 mg/L. (after calibration within 23± 5 ) ℃
- Sensor Temp Compensation : Automatic from 0 to 40 . ℃
- Panel adj. knob : ZERO knob, CAL knob.
- Battery : 006P DC 9V battery ( heavy duty ).
- Power Consumption : Approx. DC 3.5 mA.
- Operating Temp. : 0 to 50 (32 to 122 ). ℃ ℃℉ ℉
- Operating Humidity : Less than 80% RH.
GENERAL DESCRIPTION
- This Digital Dissolved Oxygen Meter is supplied with a polarographic type probe with an incorporated Temp. sensor which serves for precise Dissolved Oxygen ( DO ) and Temp. measurement.
- Applications for Aquarium, Medical research, Agriculture, Fish hatcheries, Laboratory, Water conditioning, Mining industry, Schools & Colleges, Quality control
SKU: n/a -
DIGITAL OSCILLOSCOPE
HTC DSO 50100S 0-100 Mhz Digit…
0 out of 5(0)SPECIFICATIONS
- Vertical Sensitivity : 50mV/div~500V/div
- Horizontal Time base Range : 50S/div ~ 10nS/div
- Trigger Mode : Single, Normal, Auto
- Trigger Edge : Rising Edge / Falling Edge
- Coupling : AC/DC
- Input Resistance : 1MΩ
- Maximum Test Voltage : 40V(1xprobe), 400V(10xprobe)
- Power Voltage : 100~240VACRMS, 45~60Hz, CAT II
- Power Consumption : To be less than 30VA
- Fuses : F1, 6AL, 250V; (Fuses are on power board in the unit)
FEATURES
- 14 standard signals (@2.5VPP). including sine wave, square wave, triangle wave, sawtooth, anti sawtooth, ladder wave, half wave rectification, full
wave rectification, exponential wave, logarithmic wave, pair index, open square wave, multi audio, sink pulse wave, as well as a cut-off output
function that can customize the output signal freely in which the sine wave frequency can reach 10MHz at most and other standard signals can
reach 2MHz. cutt-off frequency can reach 2MHz. - The wave output device can reach 1MHz at most an the frequency resolution of all signals can reach 1Hz (Step). It is not the half frequency step mode of half frequency division produced by other handheld devices.
- LCD : 7 INCH (800+400)
- Stored Waveform : built-in 1GB storage space, can store up to 1000 screen capture pictures + 1000 groups of waveform data 240Kbit
- Dimensions : 310mm(W) 145mm(H) 70mm(D)
SKU: n/a -
DIGITAL INSULATION TESTER
HTC 6350 IN Insulation Resista…
0 out of 5(0)SPECIFICATIONS
- Testing Voltage : 100/250/500/1000/2500/5000 V
- OUT VOLTAGE : 90~110% of the test voltage
- RANGE : 0.1M 20G for 100/250/500 V ; 0.1M 200G for 1000/2500/5000 V
- RESOLUTION : 0.01MΩ
- ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 10 digits ; 10~200GΩ ± 10% of rdg + 5 digits
AC VOLTAGE
-
- RANGE : 0 – 600V
- RESOLUTION : 1V
- ACCURACY : ±2.0% of rdg + 5 digits
FEATURES
- 3½ Digit Insulation Tester with Backlight
- 1,999 Count
- Data Hold
- Test Range 100 V to 5000 V
- POWER: AA 1.5V X 8 (Rechargeable Battery)
- Standard Accessories : Soft Carrying Case, Test Lead, Manual, Power Adaptor,AA 1.5V X 8 (Rechargeable Battery)
- Dimension : 190(H) x 155(W) x 75(D)mm
SKU: n/a -
DIGITAL INSULATION TESTER
HTC 6250IN Digital Insulation …
0 out of 5(0)SPECIFICATIONS
- Testing Voltage : 1000/2500/5000V
- OUT VOLTAGE : 90~110% of the test voltage
- RANGE : 0.1MΩ~200GΩ
- RESOLUTION : 0.01MΩ
- ACCURACY : 0.1~200MΩ ± 3% of rdg + 5digits ; 200MΩ~10GΩ ± 5% of rdg + 5 digits ; 10~200GΩ ± 10% of rdg + 5 digits
AC VOLTAGE
-
- RANGE : 0 – 600V
- RESOLUTION : 1V
- ACCURACY : ±2.0% of rdg + 5 digits
FEATURES
- 3½ Digit Insulation Tester with Backlight
- 1,999 Count
- Data Hold
- Auto Ranging
- 3 in 1 Insulation Resistance Phase Testing / Voltage Testing & Adaptor
- POWER: AA 1.5V X 8
- Standard Accessories : Hard Carrying Case, Test Lead, Manual, Power Adaptor
- Dimension : 190(H) x 155(W) x 75(D)m
SKU: n/a -
DIGITAL INSULATION TESTER
HIOKI IR-3455 High Voltage Ins…
0 out of 5(0)SPECIFICATIONS
- Test Voltage : 250 V to 5.00 kV DC, (Possible in 25 V steps between 250 V and 1 kV and in 100 V steps between 1 and 5 kV)
- Measurement Range :
0.00 MΩ to 500 GΩ (250 V)
0.00 MΩ to 1.00 TΩ (500 V)
0.00 MΩ to 2.00 TΩ (1 kV)
0.00 MΩ to 5.00 TΩ (2.5 kV)
0.00 MΩ to 10.0 TΩ (5 kV) - Measurement Current : 1 mA (Test voltage 250 V to 1.00 kV), 0.5 mA (Test voltage 1.10 kV to 2.50 kV) 0.25 mA (Test voltage 2.60 kV to 5.00 kV), Short-circuit current: 2 mA or less
- Resistance Range : 10 MΩ to 10 TΩ, 7 ranges (auto range)
- Accuracy :
±5% rdg. ±5 dgt. Up to [Test voltage (setting value)/Resistance measurable at 100 nA]
±20% rdg. ±5 dgt. [Test voltage (setting value)/Resistance measurable at 100 nA] to [Test voltage (setting value)/Resistance measurable at 1 nA] or 500 GΩ
±30% rdg. ±50 dgt. [Test voltage (setting value)/Resistance measurable at 1 nA] or 501 GΩ to 9.99 TΩ - Leakage current measurement : 1.00 nA to 1.20 mA, 6 ranges (current measurement that occurs when test voltage is generated)
Accuracy ±2.5% rdg. ±5 dgt. (1 mA range); refer to complete catalog for other ranges - Voltage measurement : ±50 V to ±1.00 kV DC, 50 V to 750 V AC (50/60 Hz),
Accuracy: ±5 % rdg. ±5 dgt. , Input resistance: Approx. 10 MΩ - Temperature measurement : -10.0 ˚C to 70.0 ˚C, 3 ranges (used with optional sensor)
Accuracy ±1.0 ˚C (0.0 ˚C to 40.0 ˚C); refer to complete catalog for other ranges - Other Functions : Insulation Diagnosis (Temperature compensation, PI/DAR display, Step voltage test), Data memory, Communication (USB 2.0, PC application software), auto discharge, hot conductor warning indication, etc.
- Digital LCD, max. 999 dgt. with backlight, Bar graph display
- Dimensions and Mass : 260 mm (10.24 in)W × 250.6 mm (9.87 in)H × 119.5 mm (4.70 in)D, 2.8 kg (98.8 oz)
- Included Accessories : Test lead 9750-01 ×1, Test lead 9750-02 ×1, Test lead 9750-03 ×1, Alligator clip 9751-01 ×1, Alligator clip 9751-02 ×1, Alligator clip 9751-03 ×1, Instruction manual ×1, LR6 (AA) alkaline batteries ×6, USB cable ×1, PC application software (CD-R) ×1
FEATURES
- Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
- Wide testing voltage range, up to 5.00 kV from 250 V DC
- Wide measurement insulation range, up to 10 TΩ
- PI (Polarization Index) and DAR (Dielectric Absorption Ratio) automatically calculated / display
- Extended operating temperature range of -10°C to 50°C
- Data memory function to reduce handwritten notes
- Bright LED luminous scale
SKU: n/a -
DIGITAL INSULATION TESTER
Fluke 1503 Insulation Resistan…
0 out of 5(0)SPECIFICATIONS
- AC/DC Voltage Measurement
Range : 600.0 V
Resolution : 0.1V
Accuracy : 50 Hz to 400 Hz ±(% of Rdg + Digits) ±(2% + 3) - Earth Bond Resistance Measurement
Range : 20.00 Ω to 20.00 kΩ
Resolution : 0.01 Ω to 0.01 kΩ
Accuracy : ±(1.5% + 3) - Insulation Specifications
Range : 0.01 MΩ to 2000 MΩ
Test Voltage : 500 V, 1000 V
Test Voltage Accuracy : + 20%, – 0% - Storage temperature : -40°C to 60°C (-40°F to 140°F)
- Operating temperature : -20°C to 55°C (-4°F to 131°F)
- Vibration : Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
- Safety : Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
- Certifications : CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
- Size : 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
- Weight : 550g
- IP Rating : IP40
FEATURES
- A rugged, compact insulation resistance tester for residential and commercial electricians
- Performs insulation tests from 0.01 MΩ to 2000 MΩ
- Offers two insulation test voltages: 500 V and 1000 V
- Includes live circuit detection to prevent insulation test if voltage >30 V is detected
- Measures resistance from 0.01 Ω to 20.00 kΩ
SKU: n/a - AC/DC Voltage Measurement
-
DIGITAL CALIPERS
Mitutoyo 500-754-10 Digital Ve…
0 out of 5(0)SPECIFICATIONS
- Range : 0 to 12″ (0 to 300 mm)
- Resolution : 0.0005″ (0.01 mm)
- Accuracy : ±0.0015″
- Repeatability : 0.0005″ (0.01 mm)
- Type : IP67 model without SPC data output
- Maximum Response Speed : Unlimited
- Display : LCD
- Battery Type: Approximately 3 years under normal use (1 year: over 12″ [300 mm] models)
- Length Standard : ABSOLUTE electromagnetic induction type linear encoder
- Dust/Water Protection Level : IP67
- Dimensions : 45 x 14 x 3.6 cm; 789.25 Grams
- Weight : 789g
FEATURES
- Can be used in workshop conditions exposed to coolant, water, dust, or oil
- Easy to use – no need to wipe or clean the scale
- Advanced design styling
- Incorporates absolute measurement system
- Automatic power on/off
- With thumb roller
- Supplied in fitted plastic case
SKU: n/a -
DIGITAL CALIPERS
Mitutoyo 500-197-30 Advanced O…
0 out of 5(0)SPECIFICATIONS
- Range : 0 to 8″/0 to 200 mm
- Resolution : 0.0005″/0.01 mm
- Accuracy : ±0.0010″/±0.02 mm
- Repeatability : 0.0005″/0.01 mm
- Units : Metric, Inch
- Maximum Response Speed : Unlimited
- Display : LCD
- Battery : Type: SR44 938882 Life: Approximately 5 years under normal use
- Length Standard : ABSOLUTE electromagnetic induction type linear encoder
- Weight : 6.98 oz (198 g)
FEATURES
- ABSOLUTE (ABS) linear scale eliminates the need for setting the origin point every time the micrometer is powered on; overspeed errors are also eliminated
- Stainless steel construction protects caliper components and ensures accurate performance for longer duration
- Functions include Origin Set, Zero-Setting, Data Output and inch/mm conversion
- Alarm: Low Voltage, counting value composition error
- A battery life of approximately 3.5 years has been achieved under normal use
- The slider configuration features an ergonomic, thumb-friendly shape
- Step-measurement capable
- Font height of 0.35″ (9 mm) alleviates fatigue with the high-contrast LCD
SKU: n/a
Showing 16–30 of 81 results